• Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
  • Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
  • Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
  • Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
  • Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
  • Showering Room Heating Air to Water Heat Pump Electric Small Water Heater

Showering Room Heating Air to Water Heat Pump Electric Small Water Heater

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Samples:
US$ 2000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Product Details
  • Previous Order Show
Overview

Basic Info.

Model NO.
DFT-012CCSE3
Certification
CE, CB
Power Supply (V/pH/Hz)
380~415/3/50
ERP Level (35ºC)
a+++
Max Input Power (Kw)
5.50
Max Input Current (a)
10.50
Rated Water Flow (M³/H)
1.80
Fan Quantity
1
Sound Pressure at 1m Distance (dB(a))
44
Max Outlet Water Temperature (°c)
75
Water Piping Connections
DN 25 (1")
Water Pressure Drop (Max) (Kpa)
25
Transport Package
Cartons
Specification
1285*455*930mm
Trademark
Smad or OEM
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
50000pieces/Year

Product Description

Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
 
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
 

Product Description

 
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
High end finned tube exchanger, specific hydrophilic coating, not easy to accumulate water and ash, rapid elmination of the moisture, greatly improve the heating efficiency.

Ultra-silence fan blade, adopt frameless horizontal axial-flow type design and materials with high thermal conductivity,  lower drag, vibration and noise
 
Panasonic DC inverter compressor, using EVI technology and automatically switch into heating or cooling working mode according ambient temperature, stable running at -30C
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
 
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
DC inverter motor,automatic variable speed control, little vibration, low noise, low energy

High end refined display, optional high end color display screen to better reflect excellent quality
 

Product Parameters

   
Model: DFT-006CCSE1 DFT-012CCSE1 DFT-012CCSE3 DFT-018CCSE1 DFT-018CCSE3
Power Supply V/Ph/Hz 220~240/1/50 220~240/1/50 380~415/3/50 220~240/1/50 380~415/3/50
Nominal Heating (Max)      (A7/6ºC,W30/35ºC) Heating Capacity      kW 3.0~9.1 5.5~15.1 5.5~15.1 7.5~22.1 7.5~22.1
Power Input kW 0.65~2.29 1.08~3.9 1.08~3.9 1.5~6.8 1.5~6.8
Current Input A 2.8~9.1 4.5~17.0 1.8~6.9 6.9~31.1 2.7~12.3
Nominal Heating (Max)    (A7/6ºC,W47/55ºC) Heating Capacity      kW 2.85~8.50 5.0~13 5.0~13 7.0~18.9 7.0~18.9
Power Input kW 0.95~2.85 1.75~4.96 1.75~4.96 2.15~7.35 2.15~7.35
Current Input A 2.9~9.2 4.6~17.1 1.9~7.0 7.0~31.3 2.8~12.4
Nominal Cooling  (Max) (A35/24ºC,W12/7ºC) Cooling Capacity      kW 1.25~5.8 3.65~10.2 3.65~10.2 4.5~17.7 4.5~17.7
Power Input kW 0.65~2.35 1.12~4.16 1.12~4.16 1.80~7.30 1.80~7.30
Current Input A 2.9~10.4 4.8~17.3 2.0~7.8 7.8~32.4 3.3~12.9
ERP Level(Outlet water temp. at 35ºC) / A+++ A+++ A+++ A+++ A+++
MAX.  input power kW 3.00 5.50  5.50  7.50 9.00
MAX. input current  A 13.50 24.50 10.50 35.00 16.00
Refrigerant / Weight   / R290 R290 R290 R290 R290
Rated water flow m³/h 1.00  1.80  1.80  3.00  3.00 
Fan quantity / 1 1 1 2 2
Fan motor type / DC inverter
Compressor / DC inverter 
Circulating pump / Inverter type / Built-in
IP Class / IPX4
Sound pressure at 1m distance dB(A) 42 44 44 48 48
Max outlet water temperature °C 75 75 75 75 75
Water piping connections / DN 25 (1") DN 25 (1") DN 25 (1") DN 32 (1-1/4") DN 32 (1-1/4")
Water Pressure drop(max) kPa 20 25 25 60 60
Operating temperature range (Heating mode) °C -30~45
Operating temperature range (Cooing mode) °C 16~45
Unpacked Dimensions ( L×D×H ) mm 1150×410×800 1285×455×930 1285×455×930 1285×455×1350 1285×455×1350
Packed Dimensions  ( L×D×H ) mm 1300×485×950 1450×530×1050 1450×530×1050 1450×530×1450 1450×530×1450
UnPacked Weight kg 90 110 110 145 145
Packed Weight kg 115 125 125 160 160
40HQ   84 64 64 32 32
 
 

Product Details


 
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
 
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
 
 

Previous Order Show



Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
Showering Room Heating Air to Water Heat Pump Electric Small Water Heater
Showering Room Heating Air to Water Heat Pump Electric Small Water HeaterShowering Room Heating Air to Water Heat Pump Electric Small Water HeaterShowering Room Heating Air to Water Heat Pump Electric Small Water HeaterShowering Room Heating Air to Water Heat Pump Electric Small Water HeaterShowering Room Heating Air to Water Heat Pump Electric Small Water Heater
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory
Plant Area
>2000 square meters
Management System Certification
ISO 9001