Certification: TUV
Working Medium: R32
Heat Source Type: Ground Source Heat Pump (GSHP)
Power Supply(V/pH/Hz): 220~240/1/50
ERP Level: a+++(Outlet Water Temp. at 35c)
Rated Input Power: 3.83
Samples:
US$ 1792.7/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Product Details
  • Previous Order Show
Overview

Basic Info.

Model NO.
DFT-010BSE1
Rated Input Current
17
Refrigerant / Weight
R32
Rated Water Flow
1.75
Fan Quantity
1
Sound Pressure at 1m Distance
51
Max Outlet Water Temperature
60
Water Piping Connections
DN 25 (1")
Specification
1100*445*850mm
Trademark
SMAD or OEM
Origin
China(Mainland)
Production Capacity
50000

Product Description

DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump

 DC Inverter Compressor Heating Or Cooling Working Mode Stable Running Heat Pump
 

Product Description


 
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
Δ pressure sensor,fast and precise 24-bit measurement , realize high precision sensing between the working temperature range from -60c to 150C 
 
1.DC inverter motor,automatic variable speed control, little vibration , low noise , low energy
2. high end refined display,optional high end color display screen to better reflect excellent quality
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
 
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
Δ ultra-silence fan blade, adopt frameless horizontal axial-flow type design and materials with high thermal conductivity, lower drag, vibration and noise 

Product Parameters

  
Model:   DFT-006BSE1 DFT-010BSE1 DFT-006BSE1 DFT-014BSE3 DFT-018BSE1 DFT-018BSE3
Power Supply V/Ph/Hz 220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50 220~240/1/50 380~415/3/50
Nominal Heating (Max)      (A7/6ºC,W30/35ºC) Heating Capacity      kW 6.46 (2.50-8.30) 10.58 (4.20-12.20) 14.45 (5.30-16.50) 14.45 (5.30-16.60) 18.77 (6.20-20.50) 18.77 (6.20-20.50)
Power Input kW 1.31  2.29 3.06  3.06  3.99  3.99 
COP W/W 4.93  4.62  4.72  4.72  4.70  4.70 
Nominal Heating (Max)    (A7/6ºC,W47/55ºC) Heating Capacity      kW 5.92  9.47 13.89  13.89  16.90  16.90 
Power Input kW 1.85  3.09 4.47  4.47  5.47  5.47 
COP W/W 3.21  3.06  3.11  3.11  3.09  3.09 
Nominal Cooling  (Max) (A35/24ºC,W12/7ºC) Cooling Capacity      kW 5.66  8.34 13.24  13.24  15.88  15.88 
Power Input kW 1.74  2.66 4.12  4.12  4.99  4.99 
EER W/W 3.25  3.14  3.21  3.21  3.18  3.18 
ERP Level(Outlet water temp. at 35ºC) / A+++ A+++ A+++ A+++ A+++ A+++
ERP Level(Outlet water temp. at 55ºC) / A++ A++ A++ A++ A++ A++
Rated input power kW 2.71 3.83 5.97  5.97  7.24 7.24
Rated input current  A 12.00 17.00 26.50 10.50 35.50 13.20
Refrigerant / Weight   / R32 R32 R32 R32 R32 R32
Rated water flow m3/h 1.10  1.75 2.50  2.50  3.20  3.20 
Fan quantity / 1 1 1 1 2 2
Fan motor type / DC inverter
Compressor / Panasonic / DC inverter / Rotary / EVI
Circulating pump /  Inverter type / Built-in
IP Class / IPX4
Sound pressure at 1m distance dB(A) 50 51 52 52 54 54
Max outlet water temperature °C 60 60 60 60 60 60
Water piping connections / DN 25 (1") DN 25 (1") DN 32 (1-1/4") DN 32 (1-1/4") DN 40 (1.5") DN 40 (1.5")
Pressure drop at rating water flow kPa 25 27 30 30 32 32
Operating temperature range (Heating mode) °C -30~45
Operating temperature range (Cooing mode) °C 16~45
Unpacked Dimensions ( L×D×H ) mm 1100×445×850 1100×445×850 1100×445×850 1100×445×850 1050×420×1250 1050×420×1250
Packed Dimensions  ( L×D×H ) mm 1150×580×1000 1150×580×1000 1150×580×1000 1150×580×1000 1100×480×1400 1100×480×1400
UnPacked Weight kg 95 107 125 125 155 155
Packed Weight kg 105 119 140 140 175 175

Product Details

 
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
 
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump

Previous Order Show



DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat PumpDC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
 DC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat PumpDC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat PumpDC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat PumpDC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat PumpDC Inverter Compressor Heating or Cooling Working Mode Stable Running Heat Pump
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory
Plant Area
>2000 square meters
Management System Certification
ISO 9001