Household Zone Heating And Cooling system Heat Pump From China
Panasonic DC inverter compressor, using EVI technology and automatically switch into heating or cooling working mode according ambient temperature, stable running at -30C.
High end finned tube exchanger, specific hydrophilic coating, not easy to accumulate water and ash, rapid elmination of the moisture, greatly improve the heating efficiency.
DC inverter motor, automatic variable speed control, little vibration, low noise, low energy.
Model: |
|
DFT-006BSE1 |
DFT-010BSE1 |
DFT-014BSE1 |
DFT-014BSE3 |
DFT-018BSE1 |
DFT-018BSE3 |
Power Supply |
V/Ph/Hz |
220~240/1/50 |
220~240/1/50 |
220~240/1/50 |
380~415/3/50 |
220~240/1/50 |
380~415/3/50 |
Nominal Heating (Max) (A7/6ºC,W30/35ºC) |
Heating Capacity |
kW |
6.46 (2.50-8.30) |
10.58 (4.20-12.20) |
14.45 (5.30-16.50) |
14.45 (5.30-16.60) |
18.77 (6.20-20.50) |
18.77 (6.20-20.50) |
Power Input |
kW |
1.31 |
2.29 |
3.06 |
3.06 |
3.99 |
3.99 |
COP |
W/W |
4.93 |
4.62 |
4.72 |
4.72 |
4.70 |
4.70 |
Nominal Heating (Max) (A7/6ºC,W47/55ºC) |
Heating Capacity |
kW |
5.92 |
9.47 |
13.89 |
13.89 |
16.90 |
16.90 |
Power Input |
kW |
1.85 |
3.09 |
4.47 |
4.47 |
5.47 |
5.47 |
COP |
W/W |
3.21 |
3.06 |
3.11 |
3.11 |
3.09 |
3.09 |
Nominal Cooling (Max) (A35/24ºC,W12/7ºC) |
Cooling Capacity |
kW |
5.66 |
8.34 |
13.24 |
13.24 |
15.88 |
15.88 |
Power Input |
kW |
1.74 |
2.66 |
4.12 |
4.12 |
4.99 |
4.99 |
EER |
W/W |
3.25 |
3.14 |
3.21 |
3.21 |
3.18 |
3.18 |
ERP Level(Outlet water temp. at 35ºC) |
/ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
ERP Level(Outlet water temp. at 55ºC) |
/ |
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
Rated input power |
kW |
2.71 |
3.83 |
5.97 |
5.97 |
7.24 |
7.24 |
Rated input current |
A |
12.00 |
17.00 |
26.50 |
10.50 |
35.50 |
13.20 |
Refrigerant / Weight |
|
/ |
R32 |
R32 |
R32 |
R32 |
R32 |
R32 |
Rated water flow |
m3/h |
1.10 |
1.75 |
2.50 |
2.50 |
3.20 |
3.20 |
Fan quantity |
/ |
1 |
1 |
1 |
1 |
2 |
2 |
Fan motor type |
/ |
DC inverter |
Compressor |
/ |
Panasonic / DC inverter / Rotary / EVI |
Circulating pump |
/ |
Inverter type / Built-in |
IP Class |
/ |
IPX4 |
Sound pressure at 1m distance |
dB(A) |
50 |
51 |
52 |
52 |
54 |
54 |
Max outlet water temperature |
°C |
60 |
60 |
60 |
60 |
60 |
60 |
Water piping connections |
/ |
DN 25 (1") |
DN 25 (1") |
DN 32 (1-1/4") |
DN 32 (1-1/4") |
DN 40 (1.5") |
DN 40 (1.5") |
Pressure drop at rating water flow |
kPa |
25 |
27 |
30 |
30 |
32 |
32 |
Operating temperature range (Heating mode) |
°C |
-30~45 |
Operating temperature range (Cooing mode) |
°C |
16~45 |
Unpacked Dimensions ( L×D×H ) |
mm |
1100×445×850 |
1100×445×850 |
1100×445×850 |
1100×445×850 |
1050×420×1250 |
1050×420×1250 |
Packed Dimensions ( L×D×H ) |
mm |
1150×580×1000 |
1150×580×1000 |
1150×580×1000 |
1150×580×1000 |
1100×480×1400 |
1100×480×1400 |
UnPacked Weight |
kg |
95 |
107 |
125 |
125 |
155 |
155 |
Packed Weight |
kg |
105 |
119 |
140 |
140 |
175 |
175 |